Part Number Hot Search : 
APL502J 60200 12E629 SDB704CA EE08150 GF32C HUR6060 BZV58C36
Product Description
Full Text Search
 

To Download S3K1000 Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
  66 3 uninterruptible power systems battery back-up times chart load % s3k700 S3K1000 s3k1600 20 45 37 27 40 21 18 12 50 14 13 10 70 9 8 6 100 5 4 3 * full/half load (in minutes). selection table capacity (va/w) catalog number volts, frequency (in/out) typical back-up time (minutes)* input plug/output receptacle approx. ship weight lbs (kg) 700/480 s3k700 120/120, 50/60 hz 5/14 (detached) 5-15p / (4)5-15r 34.1 (15.5) 1000/750 S3K1000 120/120, 50/60 hz 4/13 (detached) 5-15p / (4)5-15r 37.0 (16.8) 1440/1200 s3k1600 120/120, 50/60 hz 3/10 (attached) 5-15p / (6)5-15r 70.4 (32.0) note: back-up times are at 25 o c, 77 o f, with 100% capacity batteries and resistive loads. s3k mini-tower line-interactive ups the s3k is an economical choice for those applications requiring the performance of a sinewave output, line interac- tive ups with the mini-tower shape for cabinet installations. the s3k series protects against most severe power disturbances through state-of-the-art, line-interactive technology. most power disturbance corrections are ac - complished without transferring to the internal battery. utility power is continually protected by the s3k series upss and internal battery life is optimized. the ups has built in protection for under and over voltage conditions including low-energy lightning surges introduced on the input power source. all s3k series ups are provided with an input circuit protector and surge protected data line connectors. the s3k series upss are provided with a bat - tery test function. should the battery fail this test, the ups will display a warning to indicate that the battery needs to be replaced. features ? mini-tower design for control cabinet installation. ? automatic voltage regulation (avr) topology saves battery power for deep voltage sag situations. ? sine wave output ? user replaceable, "hot swappable" batteries (downtime for battery replacement not required). ? rs-232 communications port ? built-in surge protection ? cold start capability (dc power on) ? telephone/modem spike protection ? power management software is included (upsmon). ? 50/60 hz auto sensing ? fully digitized, microprocessor controlled ? protects against most adverse power conditions including: - frequency variations - surge - sags - spike - blackouts - over and under voltages ? two year limited warranty applications ? workstations ? plcs ? robotics and process control ? industrial automation systems ? automatic service & dispensing equipment related products ? portable mcr power conditioners ? surge protective devices ? active tracking ? filters e179213
67 3 uninterruptible power systems specifications catalog number s3k700 S3K1000 s3k1600 power rating (va/watts) 700/480 1000/750 1440*/1200 dimensions inches (mm) unit (h x w x d) 8.3 x 5.5 x 17.2 (210 x 140 x 436) 8.9 x 6.7 x 17.7 (226 x 170 x 450) shipping (h x w x d) 11.75 x 10.5 x 19.2 (300 x 265 x 492) 14.0 x 12.0 x 22.25 (358 x 307 x 581) approx. shipping weight - lbs (kg) 34.1 (15.5) 37 (16.8) 70.4 (32) input ac parameters voltage range 103-132 vac plug 6 ft. detachable with nema 5-15p attached 5-15p line to boost transfer maintains output to 120 vac; -14%, when input is 120 vac, -25% line to buck transfer maintains output to 120 vac; +10%, when input is 120 vac, +23% frequency 45-55 hz or 55-65 hz; auto sensing output ac parameters voltage 103 vac to 132 vac receptacles (4) nema 5-15r (6) nema 5-15r frequency 50 hz or 60 hz 0.5% waveform sine wave overload warning 100-110% nominal overload shutdown 200% nominal battery parameters type valve-regulated, non-spillable, lead acid battery time (mins) (fl/hl) 5/14 4/13 3/10 qty. x voltage x rating 4 x 12 v x 7 ah 6 x 12 v x 7 ah transfer time 2-4 ms typical back-up time see battery back-up times charts recharge time 4 hours to 90% rated capacity, after full discharge into resistive load environmental operating temperature +32f to +104f (0c to +40c) storage temperature +5f to +122f (-15c to +50c) relative humidity 0% to 95%, non-condensing operating elevation up to 10,000 ft. (3000 m) at 35c without derating audible noise <40 dba, (beyond 1 m) <45 dba, (beyond 1 m) agency safety ul 1778, culus listed emissions fcc part 15, subpart b, class a immunity iec 60801-2, level 4 / iec 60801-4, level 4 / ansi c62.41 category a & b * note: 1200w at 0.75 power factor equals 1600va. line cord limits total load to 1440 va (max).


▲Up To Search▲   

 
Price & Availability of S3K1000

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X